TUV Round ASTM A269 TP316 Boiler Steel Tube Anti Oxidation
Product Details
| STANDARD: | JIS, AiSi, ASTM, GB, DIN, EN | MATERIAL: | TP304L |
|---|---|---|---|
| SPECIFICATION: | ASTM A269 304L Stainless Steel Tubing,ASTM A213 SA213 TP304L | Package: | Standard Seaworthy Package |
| Processing: | Bending, Welding, Decoiling, Punching, Cutting, Moulding | Shape: | Round |
| Highlight |
astm a269 tubing,Boiler astm a269 tubing,astm a269 tp316 Boiler Tube |
||
Product Description
Description
ASTM A213 A312 A269 A511 A240 UNS S30403 304L, EN 10216-5 1.4307 stainless steel pipe is a variation of the 18% chromium – 8% nickel austenitic alloy, the most familiar and most frequently used alloy in the stainless steel family. This alloy may be considered for a wide variety of applications and exhibits good corrosion resistance, ease of fabrication, excellent formability, and high strength with low weight. Type 304L is a lower carbon variant of Grade 304 – the steel can be welded without the resulting issue of carbon precipitation precipitation of chromium carbide as heat is applied during the welding process which depletes the chromium element of the steel thus reducing its anti corrosive / oxidation effectiveness, and because of low carbon percentage, can minimizing Intergranular corrosion attack.
Specification:
Table 1. Composition ranges for ASME SA 213 304 304L 304H and EN 10216-5 1.4301 1.4307 1.4948
| Grade | – | C | Mn | Si | P | S | Cr | Mo | Ni | N |
| 304/S30400 | min.max. | -0.08 | -2.0 | -1.00 | -0.045 | -0.030 | 18.0-20.0 | – | 8.0-11.0 | – |
| EN 10216-5 1.4301 | min.max. | -0.07 | -2.0 | -1.00 | -0.040 | -0.015 | 17.00-19.5 | – | 8.0-10.5 | -0.11 |
| 304L/S30403 | min.max. | -0.035 | -2.0 | -1.00 | -0.045 | -0.030 | 18.0-20.0 | – | 8.0-12.0 | – |
| EN 10216-5 1.4307 | min.max. | -0.030 | -2.0 | -1.00 | -0.040 | -0.015 | 17.5-19.5 | – | 8.0-10.0 | -0.11 |
| 304H /S30409 | min.max. | 0.04-0.10 | -2.0 | -1.00 | -0.045 | -0.030 | 18.0-20.0 | – | 8.0-11.0 | – |
| EN 10216-5 1.4948 | min.max. | 0.04-0.08 | -2.0 | -1.00 | -0.035 | -0.015 | 17.0-19.0 | – | 8.0-11.0 | -0.11 |
| GRADE | UNS | EN | JIS | AFNOR | BS | WERKSTOFF NR. | GOST | SS |
| USA | EUROPE | JAPAN | RUSSIAN | BRITISH | GERMAN | RUSSIAN | SWEDISH | |
| SS 304L | S30403 | X2CrNi18-9 / X2CrNi19-11 | SUS 304L | Z3CN18‐10 | 304S11 | 1.4306/1.4307 | 03Х18Н11 | 2332 |


Application Industries
- Off-Shore Oil Drilling Companies
- Power Generation
- Petrochemicals
- Gas Processing
- Specialty Chemicals
- Pharmaceuticals
- Pharmaceutical Equipment
- Chemical Equipment
- Sea Water Equipment
- Heat Exchangers
- Condensers

Product Highlights
Description ASTM A213 A312 A269 A511 A240 UNS S30403 304L, EN 10216-5 1.4307 stainless steel pipe is a variation of the 18% chromium – 8% nickel austenitic alloy, the most familiar and most frequently used alloy in the stainless steel family. This alloy may be considered for a wide variety of ...
High Frequency Welding Customized Coal Fired Steam Boiler Parts Stack Economizer Coil
High Frequency Welding Customized Coal Fired Steam Boiler Parts Stack Economizer Coil Boiler economizer Boiler Economizer is the energy improving device that helps to reduce the cost of operation by saving the fuel. The economizer in Boiler tends to make the system more energy efficient. In boilers, economizers are generally designed to exchange heat with the fluid, generally water. The exhaust from the boilers is generally in the temperature range of 200°C – 250°C, so there
High Frequency Welding Boiler Spiral Fin Tube For Economizer Heat Transfer
High Frequency Welding Boiler Spiral Fin Tube For Economizer Heat Transfer Boiler economizer Boiler Economizer is the energy improving device that helps to reduce the cost of operation by saving the fuel. The economizer in Boiler tends to make the system more energy efficient. In boilers, economizers are generally designed to exchange heat with the fluid, generally water. The exhaust from the boilers is generally in the temperature range of 200°C – 250°C, so there are a huge
Heat Exchanger H Type Boiler Parts Tube For Utility Power Station Plant
High Efficient Heat Exchang H Type High Temperature Resistance Boiler Parts For Utility/Power Station Plant Product Introduce H-fin Tubes have two steel discs,with fluorescent tubes symmetrically welded together to form fins(fins of butterfly piece)creating a shape that looks somewhat like the letter"H",creating an efficient energy saving, extension heating surface.H-fin Tubes also have a high rate of fusion welds and weld tensile strength.H-fin Tube is assembled with the H
Extension Heating Surface Boiler Fin Tube For Industrial Power Plant Boiler
Energy Saving Extension Heating Surface Boiler Fin Tube For Industrial Power Plant Boiler Product Description H-fin Tubes have two steel discs,with fluorescent tubes symmetrically welded together to form fins(fins of butterfly piece)creating a shape that looks somewhat like the letter"H",creating an efficient energy saving, extension heating surface. H-fin Tubes also have a high rate of fusion welds and weld tensile strength.H-fin Tube is assembled with the H economizer,